Untitled category

Heat pumps run on dumb thermostats

Autors

Volton Editorial Team

Publicēts

A heat pump is the largest steady electrical load in winter, paired with a thermal mass that doubles as a battery. Price-aware scheduling captures spreads of 5–10x between cheap night hours and expensive mornings on the spot market — but only if the thermostat is smart enough to cooperate, which most aren't. The thermostat is the weak link.

Around half of new heating installations in Estonia today are heat pumps. The hardware caught on faster than the software did. In a modern home, the heat pump is the appliance that benefits the most from being clever about price. It is also the one most often left running on a fixed schedule from 2018.

Why does it benefit the most? Two reasons. It is the largest steady electrical load in winter, typically two to five kilowatts for hours at a time. And it works against a thermal mass — the house itself — that doubles as a battery. Heat poured into the slab and the radiators at 03:00 keeps the rooms comfortable until breakfast, by which time the spot price has already spiked and crashed.

The Estonian context makes this unusually rewarding. Elering data shows the day-ahead market regularly swinging from negative prices on windy nights to north of €500/MWh on cold weekday mornings. Static-tariff customers smooth that volatility into a flat, expensive average. Spot-aware customers, if they do nothing clever, eat the peaks raw. See Elering live prices for what a typical winter day actually looks like.

Smart control means three things in practice. First, price-aware scheduling: lean on the heat pump in the cheap night window, usually 02:00 to 06:00, and let the house coast through the morning peak. Second, gentle pre-heating: nudge the indoor setpoint up by one or two degrees during cheap hours so the house has thermal headroom to glide through expensive ones. Third, treat the domestic hot water tank as what it is, a 200 to 300 litre thermal battery, and finish heating it before sunrise rather than on demand at 08:00.

All of this rides on top of the manufacturer's weather curve, not under it. Outdoor temperature still drives base demand. Price awareness is an overlay. Modern units from NIBE, Bosch, Daikin, Mitsubishi, Panasonic and IVT expose either a cloud API or a Modbus / EEBus interface that lets an external controller shift setpoints by a degree or two without ever pushing the compressor outside its warranty envelope. Manufacturers like NIBE have published these integration paths for years; the question is whether anything is actually using them.

A heat pump on a fixed schedule, with no price input, is leaving most of its potential value on the table in a 2025 Estonian winter. The hardware is already excellent. The thermostat is the weak link.

Comfort is the part people worry about, and they are right to. A well-tuned controller stays inside a ±1 °C band around the resident's target. Nobody should feel the optimisation. If you do feel it, the bands are too wide or the pre-heat is too aggressive, and that is a tuning problem, not a fundamental one. The same logic applies to floor heating, where the slab's inertia is your friend: it stores heat for hours and releases it slowly, which is exactly the behaviour you want when prices are spiking.

Heat pumps also pair naturally with the rest of a flexible home. A rooftop array running into a midday surplus can dump that energy straight into the hot water tank rather than exporting it at near-zero feed-in tariffs, a pattern covered in the sister post on solar optimisation. A home battery, covered separately, handles the short fast peaks; the heat pump handles the long slow ones. They are complementary, not competing.

Volton Home, our retail supply, runs this for around six hundred Estonian homes. The customer connects the heat pump in the app once, the optimiser pulls tomorrow’s prices each afternoon, and the schedule is rewritten overnight. The reported average bill saving across the whole appliance mix is in the low thirties of a percent, and in a heated house most of that saving is the soojuspump pulling its weight.

Lasīt vairāk

Cheap electricity in Estonia — hero

How Can We Reach Cheap Electricity in Estonia?

Why simply building more wind and solar is not enough — and how hybrid parks, storage and flexibility are the real path to cheap electricity in Estonia.

1 min lasīšanas
1 MW / 2 MWh BESS on the Estonian flexibility market — hero

How Much Can You Really Earn with a Battery on Estonia's Flexibility Markets?

A real-world case study of the economics of a 1 MW / 2 MWh BESS project on the mFRR market in Estonia — capex, monthly costs, revenue and 15-month payback.

1 min lasīšanas
Electricity markets explained — hero

Electricity Markets Explained: From Spot Prices to Frequency Reserves

A plain-language guide to the key terms used in wholesale and flexibility markets — spot price, aFRR, mFRR, BRP, BSP, BESS and aggregators.

1 min lasīšanas
2026 BESS net-metering amendment — hero

In 2026, building Battery Energy Storage in Estonia is getting even more profitable

From 2026 Estonia will calculate grid fees and renewable charges on net consumption only — a major step that can save a 100 MW BESS over €3M per year.

1 min lasīšanas
Balance Service Provider — high-voltage transmission pylons at sunset

What is a Balance Service Provider (BSP)?

A BSP is a market participant certified by the TSO to deliver balancing services — frequency reserves like FCR, aFRR and mFRR. Here is how the role works in Europe and Estonia, and where aggregators fit in.

1 min lasīšanas
Nord Pool — wholesale power market trading screen with charts

Inside Nord Pool

Nord Pool clears the day-ahead and intraday markets across the Nordics, Baltics, and much of Western Europe. We unpack the auction, market coupling, and what it takes to be a member.

1 min lasīšanas
Balance Responsible Party — high voltage power line crossing a Norwegian mountain landscape

Balance Responsible Party (BRP): who pays for every imbalanced kilowatt-hour

Every kilowatt-hour on the grid has a Balance Responsible Party that is contractually accountable for it. Here is how the BRP regime works under Elering and why aggregation matters.

1 min lasīšanas
ACER and REMIT Article 15 — glass-walled European institutional building

REMIT Article 15 and the algorithmic-trading notification

REMIT Article 15 brings algorithmic energy trading under ACER oversight. We explain the notification regime, what counts as algorithmic, and why this matters for asset owners.

1 min lasīšanas
Day-ahead electricity market — trading screen with charts

Day-ahead market: pricing an hour that has not happened yet

Every day at noon CET, an algorithm sets the price of electricity for every hour of tomorrow. The day-ahead auction is the reference the rest of the energy industry hangs off.

1 min lasīšanas
Intraday electricity market — server rack with blinking green LEDs

Intraday market — after the auction, reality drifts

After the noon auction closes, intraday opens — a continuous order book that runs until close to delivery. It is where flexibility actually pays.

1 min lasīšanas
Power futures — handshake on a long-dated electricity contract

Power futures: how a wind farm gets its loan approved

Forward contracts on electricity, traded on Nasdaq Commodities and EEX, let buyers fix a price for delivery months or years ahead. Most settle financially against the day-ahead spot.

1 min lasīšanas
Power Purchase Agreements — wind turbine against blue sky

PPAs — how long-term contracts financed the renewable boom

Power Purchase Agreements are 5–15 year bilateral contracts between renewable generators and corporate offtakers. They probably did more for Europe’s energy transition than any subsidy.

1 min lasīšanas
FCR — high-voltage transmission pylons at sunset

FCR: what catches the grid when a reactor trips

Frequency Containment Reserve activates within 30 seconds of a frequency deviation, fully automatic, no TSO signal. Batteries dominate it. It is what made grid-scale storage economically viable.

1 min lasīšanas
aFRR — server racks and grid control systems

aFRR, the reserve in the middle

Automatic Frequency Restoration Reserve activates in ~30 seconds via TSO control signal, follows it on a 4-second cycle, and pulls the grid back to 50 Hz. Estonia joined the EU PICASSO platform on 9 April 2025; cross-border aFRR clears every 4 seconds across the continent.

1 min lasīšanas
mFRR — wind turbine farm landscape

mFRR — where Estonian battery profits come from

Manual Frequency Restoration Reserve is activated by a human operator, with full delivery in 12.5 minutes. In Estonia, it is currently the most lucrative balancing market for batteries.

1 min lasīšanas
Smart EV charging — electric car plugged into a charging station

EV charging: plug in at six, leave at eight

A 50 kWh top-up costs about €15 at 02:00 or €45 at 18:00. Smart charging on OCPP-compatible wallboxes re-optimises every day against tomorrow’s spot prices, saving 50-70% on EV charging.

1 min lasīšanas
Smart solar — house with solar panels on the roof

When your solar panels lose you money

On a sunny April afternoon, a 10 kW rooftop array can produce 8 kWh and lose money in the same hour. Smart self-consumption + curtailment + battery routing is what makes solar pay in 2025 Estonia.

1 min lasīšanas
Smart home battery — wall-mounted residential energy storage unit

Home batteries, two stacked revenue streams

A 10 kWh home battery earns ~€730/year from spot arbitrage alone. Stacked with aggregated frequency-reserve revenue (only available via a BSP), the same hardware can clear above 10% IRR.

1 min lasīšanas
Smart floor heating — heating cables before screed

Floor heating is the most flexible heater in your house

Resistive floor heating is in most Estonian homes and most of it runs dumb. The slab is essentially a thermal battery; price-aware scheduling captures spot-price spreads while the room temperature barely moves.

1 min lasīšanas
Smart boiler — wall-mounted hot-water tank in a utility room

The cheapest battery in your home is the boiler

A 100-150L hot-water tank stores 4-8 kWh as heat — about the same capacity as a small home battery. A €50 smart relay on the existing tank pays itself back within the first heating season.

1 min lasīšanas
Heat pumps run on dumb thermostats | Volton