Resistive floor heating is in most Estonian homes and most of it runs dumb. The slab is essentially a thermal battery — heat it during cheap night hours and the temperature barely moves until morning. Price-aware scheduling captures spot-price spreads that are completely invisible to the room thermostat. The most flexible heater in the house, hidden under the tile.

Almost every Estonian home has electric underfloor heating somewhere. Bathrooms invariably. Kitchens often. New builds, the entire ground floor. It is so familiar it is invisible — which is roughly why nobody talks about it as one of the best flexibility assets a home owns.

It should be talked about that way. A heated screed floor stores hours of warmth. Heat it during cheap hours and the room stays warm for four to eight hours after, even with the circuit off. That is a thermal battery sitting under the tile, with a discharge curve measured in hours rather than minutes.

Resistive floor heating is everywhere here. Bathrooms almost universally, kitchens often, entire ground floors in new builds. Typical loading is 100 to 150 watts per square metre, so a heated kitchen draws as much as a Level 2 EV charger, and a whole-floor install in a new house can pull 6 to 8 kW. That is real load, and it is sitting under the tile doing nothing clever about day-ahead spot prices.

Why the floor beats the heat pump for short-window arbitrage

A heat pump has a compressor that prefers long, steady runs. Cycling it every hour to chase cheap quarters of the day shortens its life and tanks its seasonal efficiency. A floor-heating circuit has none of that baggage. There is no minimum runtime, no defrost cycle, no oil to settle. A relay clicks, current flows, the wire warms up. You can switch it a hundred times a day and nothing complains.

Combine that with the slab itself. A heated screed is essentially a battery for low-grade heat, with a discharge curve measured in hours rather than minutes. Heat it one or two degrees above your comfort target during the 02:00 to 05:00 trough, let it coast through the 07:00 to 09:00 morning peak, top it up again midday if solar pushes prices into the floor. The room temperature barely wobbles. The bill does.

Efficiency is the obvious objection. A heat pump turns one kilowatt-hour of electricity into three or four kilowatt-hours of heat; a resistive floor turns it into exactly one. That is a 3 to 4x penalty on paper. In practice the spot-price spread between a cheap winter night and an expensive winter morning is routinely 5 to 10x, which more than covers the gap when the floor is used as a comfort layer rather than the primary heat source. In homes without a heat pump, smart-controlled floor heating can carry a third to half of the daily load.

The wiring is undramatic. Most modern floor-heating thermostats from Heatit, Devi, OJ Electronics, Uponor and Microtemp speak Z-Wave, Modbus or OpenTherm out of the box. Older installs with a dumb dial thermostat are even simpler: drop a smart relay in the junction box upstream of the thermostat, leave the thermostat at its comfort setpoint, and let the relay decide when current is allowed through. Coordinate across zones so you do not fire every circuit in the house at the same minute and trip the main fuse, and weight the schedule with a weather forecast so the slab is already warm when a cold front lands at dawn.

The most flexible heater in the average Estonian house is probably the one buried in the bathroom floor. It is small, it is always on, the owner barely thinks about it, and it will happily shift its consumption around the day if something tells it to.

Volton does the telling. Through Volton Home the optimiser talks to whichever thermostat the home has, or to a retrofit relay where the existing thermostat is too old to talk, and schedules each zone against tomorrow's prices. The homeowner keeps one comfort temperature in the app and never has to think about the rest. Floor heating turns out to be one of the most useful loads to optimise — slow enough to ride out the cheap-hour windows without losing comfort.

Skaityti toliau

Cheap electricity in Estonia — hero

How Can We Reach Cheap Electricity in Estonia?

Why simply building more wind and solar is not enough — and how hybrid parks, storage and flexibility are the real path to cheap electricity in Estonia.

1 min skaitymo
1 MW / 2 MWh BESS on the Estonian flexibility market — hero

How Much Can You Really Earn with a Battery on Estonia's Flexibility Markets?

A real-world case study of the economics of a 1 MW / 2 MWh BESS project on the mFRR market in Estonia — capex, monthly costs, revenue and 15-month payback.

1 min skaitymo
Electricity markets explained — hero

Electricity Markets Explained: From Spot Prices to Frequency Reserves

A plain-language guide to the key terms used in wholesale and flexibility markets — spot price, aFRR, mFRR, BRP, BSP, BESS and aggregators.

1 min skaitymo
2026 BESS net-metering amendment — hero

In 2026, building Battery Energy Storage in Estonia is getting even more profitable

From 2026 Estonia will calculate grid fees and renewable charges on net consumption only — a major step that can save a 100 MW BESS over €3M per year.

1 min skaitymo
Balance Service Provider — high-voltage transmission pylons at sunset

What is a Balance Service Provider (BSP)?

A BSP is a market participant certified by the TSO to deliver balancing services — frequency reserves like FCR, aFRR and mFRR. Here is how the role works in Europe and Estonia, and where aggregators fit in.

1 min skaitymo
Nord Pool — wholesale power market trading screen with charts

Inside Nord Pool

Nord Pool clears the day-ahead and intraday markets across the Nordics, Baltics, and much of Western Europe. We unpack the auction, market coupling, and what it takes to be a member.

1 min skaitymo
Balance Responsible Party — high voltage power line crossing a Norwegian mountain landscape

Balance Responsible Party (BRP): who pays for every imbalanced kilowatt-hour

Every kilowatt-hour on the grid has a Balance Responsible Party that is contractually accountable for it. Here is how the BRP regime works under Elering and why aggregation matters.

1 min skaitymo
ACER and REMIT Article 15 — glass-walled European institutional building

REMIT Article 15 and the algorithmic-trading notification

REMIT Article 15 brings algorithmic energy trading under ACER oversight. We explain the notification regime, what counts as algorithmic, and why this matters for asset owners.

1 min skaitymo
Day-ahead electricity market — trading screen with charts

Day-ahead market: pricing an hour that has not happened yet

Every day at noon CET, an algorithm sets the price of electricity for every hour of tomorrow. The day-ahead auction is the reference the rest of the energy industry hangs off.

1 min skaitymo
Intraday electricity market — server rack with blinking green LEDs

Intraday market — after the auction, reality drifts

After the noon auction closes, intraday opens — a continuous order book that runs until close to delivery. It is where flexibility actually pays.

1 min skaitymo
Power futures — handshake on a long-dated electricity contract

Power futures: how a wind farm gets its loan approved

Forward contracts on electricity, traded on Nasdaq Commodities and EEX, let buyers fix a price for delivery months or years ahead. Most settle financially against the day-ahead spot.

1 min skaitymo
Power Purchase Agreements — wind turbine against blue sky

PPAs — how long-term contracts financed the renewable boom

Power Purchase Agreements are 5–15 year bilateral contracts between renewable generators and corporate offtakers. They probably did more for Europe’s energy transition than any subsidy.

1 min skaitymo
FCR — high-voltage transmission pylons at sunset

FCR: what catches the grid when a reactor trips

Frequency Containment Reserve activates within 30 seconds of a frequency deviation, fully automatic, no TSO signal. Batteries dominate it. It is what made grid-scale storage economically viable.

1 min skaitymo
aFRR — server racks and grid control systems

aFRR, the reserve in the middle

Automatic Frequency Restoration Reserve activates in ~30 seconds via TSO control signal, follows it on a 4-second cycle, and pulls the grid back to 50 Hz. Estonia joined the EU PICASSO platform on 9 April 2025; cross-border aFRR clears every 4 seconds across the continent.

1 min skaitymo
mFRR — wind turbine farm landscape

mFRR — where Estonian battery profits come from

Manual Frequency Restoration Reserve is activated by a human operator, with full delivery in 12.5 minutes. In Estonia, it is currently the most lucrative balancing market for batteries.

1 min skaitymo
Smart heat pump — outdoor air-source unit next to a building

Heat pumps run on dumb thermostats

A heat pump is the largest steady electrical load in winter, paired with a thermal mass that doubles as a battery. Price-aware scheduling captures spreads of 5-10x between cheap night hours and expensive mornings.

1 min skaitymo
Smart EV charging — electric car plugged into a charging station

EV charging: plug in at six, leave at eight

A 50 kWh top-up costs about €15 at 02:00 or €45 at 18:00. Smart charging on OCPP-compatible wallboxes re-optimises every day against tomorrow’s spot prices, saving 50-70% on EV charging.

1 min skaitymo
Smart solar — house with solar panels on the roof

When your solar panels lose you money

On a sunny April afternoon, a 10 kW rooftop array can produce 8 kWh and lose money in the same hour. Smart self-consumption + curtailment + battery routing is what makes solar pay in 2025 Estonia.

1 min skaitymo
Smart home battery — wall-mounted residential energy storage unit

Home batteries, two stacked revenue streams

A 10 kWh home battery earns ~€730/year from spot arbitrage alone. Stacked with aggregated frequency-reserve revenue (only available via a BSP), the same hardware can clear above 10% IRR.

1 min skaitymo
Smart boiler — wall-mounted hot-water tank in a utility room

The cheapest battery in your home is the boiler

A 100-150L hot-water tank stores 4-8 kWh as heat — about the same capacity as a small home battery. A €50 smart relay on the existing tank pays itself back within the first heating season.

1 min skaitymo